YXC7V-A (TSE) - NA2XSY (IEC) 20,3/35 kV
YXC7V-A (TSE) - NA2XSY (IEC) 20,3/35 kV
20,3/35 kV XLPE insulated single core cables with aluminium conductor
Read moreYXC7V-A 1x50 mm2
Nexans ref. 10571531
- Packaging: Drum (1000m)
- Conductor cross-section: 50 mm²
- Average insulation thickness: 8.5 mm
- Conductor diameter: - mm
- Nominal outer sheath thickness: - mm
YXC7V-A 1x95 mm2
Nexans ref. 10541048
- Packaging: Drum (1000m)
- Conductor cross-section: 95 mm²
- Average insulation thickness: 8.5 mm
- Conductor diameter: 11.55 mm
- Nominal outer sheath thickness: 2.2 mm
YXC7V-A 1x120 mm2
Nexans ref. 10538006
- Packaging: Drum (1000m)
- Conductor cross-section: 120 mm²
- Average insulation thickness: 8.5 mm
- Conductor diameter: 12.95 mm
- Nominal outer sheath thickness: 2.2 mm
YXC7V-A 1x150 mm2
Nexans ref. 10541049
- Packaging: Drum (1000m)
- Conductor cross-section: 150 mm²
- Average insulation thickness: 8.5 mm
- Conductor diameter: 14.5 mm
- Nominal outer sheath thickness: 2.3 mm
YXC7V-A 1x150 mm2
Nexans ref. 10563703
- Packaging: Drum (1000m)
- Conductor cross-section: 150 mm²
- Average insulation thickness: 8.5 mm
- Conductor diameter: 14.5 mm
- Nominal outer sheath thickness: 2.3 mm
YXC7V-A 1x150 mm2
Nexans ref. 10568530
- Packaging: Drum (1000m)
- Conductor cross-section: 150 mm²
- Average insulation thickness: 8.5 mm
- Conductor diameter: 14.5 mm
- Nominal outer sheath thickness: 2.3 mm
YXC7V-A 1x185 mm2
Nexans ref. 10532037
- Packaging: Drum (1000m)
- Conductor cross-section: 185 mm²
- Average insulation thickness: 8.5 mm
- Conductor diameter: - mm
- Nominal outer sheath thickness: - mm
YXC7V-A 1x240 mm2
Nexans ref. 10564822
- Packaging: Drum (1000m)
- Conductor cross-section: 240 mm²
- Average insulation thickness: 8.5 mm
- Conductor diameter: 18.4 mm
- Nominal outer sheath thickness: 2.4 mm
YXC7V-A 1x300 mm2
Nexans ref. 10564122
- Packaging: Drum (1000m)
- Conductor cross-section: 300 mm²
- Average insulation thickness: 8.5 mm
- Conductor diameter: 20.5 mm
- Nominal outer sheath thickness: 2.5 mm
YXC7V-A 1x400 mm2
Nexans ref. 10564319
- Packaging: Drum (1000m)
- Conductor cross-section: 400 mm²
- Average insulation thickness: 8.5 mm
- Conductor diameter: - mm
- Nominal outer sheath thickness: - mm
YXC7V-A 1x400 mm2
Nexans ref. 10568531
- Packaging: Drum (1000m)
- Conductor cross-section: 400 mm²
- Average insulation thickness: 8.5 mm
- Conductor diameter: 23.6 mm
- Nominal outer sheath thickness: 2.6 mm
YXC7V-A 1x500 mm2
Nexans ref. 10568125
- Packaging: Drum (1000m)
- Conductor cross-section: 500 mm²
- Average insulation thickness: 8.5 mm
- Conductor diameter: 26.0 mm
- Nominal outer sheath thickness: 2.7 mm
YXC7V-A 1x630 mm2
Nexans ref. 10581479
- Packaging: Drum (1000m)
- Conductor cross-section: 630 mm²
- Average insulation thickness: 9.0 mm
- Conductor diameter: 30.1 mm
- Nominal outer sheath thickness: 2.04 mm
Description
Description
Standards
-
NationalTSEK
Application
These are cables with low dielectric losses used in energy network with sudden load changes. Laid in residental or industrial areas, underground or in ducts.
Construction
- Conductor:Aluminium
- Conductor screen:Semi-conducting compound (XLPE)
- Insulation:XLPE
- Insulation screen:Semi-conducting compound (XLPE)
- Semi-conducting tape:Crape tape
- Metallic screen:Concentric / Copper wires + copper tape
- Outer sheath:PVC
Characteristics
Characteristics
Construction characteristics
Construction characteristics
Conductor flexibility
Class 2
Dimensional characteristics
Dimensional characteristics
Number of cores
1
Electrical characteristics
Electrical characteristics
Rated Voltage Uo/U (Um)
20.3 / 35 kV
Usage characteristics
Usage characteristics
Operating temperature, range
-20 ... 90 °C
Short-circuit max. conductor temperature
250 °C
Flame retardant
IEC 60332-1-2
Bending factor when laying
12 (xD)
Max. conductor temperature in service
90 °C