N2XH Single Core Cables B2ca

Products

N2XH 1G240 mm2

Nexans ref. 10572986

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Green / Yellow
  • Perm. current rating in air 30°C - flat formation: 781 A
  • Permissible current rating buried/direct 20°C: 375 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1G240 mm2 Flex

Nexans ref. 10572989

  • Packaging: Drum (1000m)
  • Conductor shape: Round, multi stranded
  • Conductor flexibility: Flexible class 5
  • Core identification: Green / Yellow
  • Perm. current rating in air 30°C - flat formation: 781 A
  • Permissible current rating buried/direct 20°C: 375 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1G300 mm2

Nexans ref. 10572985

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Green / Yellow
  • Perm. current rating in air 30°C - flat formation: 902 A
  • Permissible current rating buried/direct 20°C: 419 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1G400 mm2

Nexans ref. 10572984

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Green / Yellow
  • Perm. current rating in air 30°C - flat formation: 1085 A
  • Permissible current rating buried/direct 20°C: 464 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1G95 mm2

Nexans ref. 10572987

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Green / Yellow
  • Perm. current rating in air 30°C - flat formation: 430 A
  • Permissible current rating buried/direct 20°C: 226 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x10 mm2

Nexans ref. 10541918

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 100 A
  • Permissible current rating buried/direct 20°C: 65 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: -

 

N2XH 1x120 mm2

Nexans ref. 10540556

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 500 A
  • Permissible current rating buried/direct 20°C: 257 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: -

 

N2XH 1x120 mm2

Nexans ref. 10588157

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 500 A
  • Permissible current rating buried/direct 20°C: 257 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x120 mm2

Nexans ref.

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 500 A
  • Permissible current rating buried/direct 20°C: 257 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x150 mm2

Nexans ref. 10541115

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 577 A
  • Permissible current rating buried/direct 20°C: 287 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: -

 

N2XH 1x150 mm2

Nexans ref. 10572966

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 577 A
  • Permissible current rating buried/direct 20°C: 287 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x150 mm2

Nexans ref. 10591368

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 577 A
  • Permissible current rating buried/direct 20°C: 287 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x150 mm2

Nexans ref. 10592526

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 577 A
  • Permissible current rating buried/direct 20°C: 287 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x16 mm2

Nexans ref. 10541113

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 135 A
  • Permissible current rating buried/direct 20°C: 84 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: -

 

N2XH 1x185 mm2

Nexans ref. 10541116

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 661 A
  • Permissible current rating buried/direct 20°C: 324 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: -

 

N2XH 1x2.5 mm2

Nexans ref. 10556670

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 42 A
  • Permissible current rating buried/direct 20°C: 30 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: -

 

N2XH 1x240 mm2

Nexans ref. 10540557

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 781 A
  • Permissible current rating buried/direct 20°C: 375 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: -

 

N2XH 1x240 mm2

Nexans ref. 10572965

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 781 A
  • Permissible current rating buried/direct 20°C: 375 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x240 mm2

Nexans ref. 10588159

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 781 A
  • Permissible current rating buried/direct 20°C: 375 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x240 mm2

Nexans ref. 10591369

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 781 A
  • Permissible current rating buried/direct 20°C: 375 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x240 mm2 Flex

Nexans ref. 10572983

  • Packaging: Drum (1000m)
  • Conductor shape: Round, multi stranded
  • Conductor flexibility: Flexible class 5
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 781 A
  • Permissible current rating buried/direct 20°C: 375 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x25 mm2

Nexans ref. 10540552

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 182 A
  • Permissible current rating buried/direct 20°C: 107 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance:

 

N2XH 1x300 mm2

Nexans ref. 10541117

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 902 A
  • Permissible current rating buried/direct 20°C: 419 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: -

 

N2XH 1x300 mm2

Nexans ref. 10572964

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 902 A
  • Permissible current rating buried/direct 20°C: 419 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x300 mm2

Nexans ref. 10588113

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 902 A
  • Permissible current rating buried/direct 20°C: 419 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x300 mm2 Flex

Nexans ref. 10572981

  • Packaging: Drum (1000m)
  • Conductor shape: Round, multi stranded
  • Conductor flexibility: Flexible class 5
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 902 A
  • Permissible current rating buried/direct 20°C: 419 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x35 mm2

Nexans ref. 10540553

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 226 A
  • Permissible current rating buried/direct 20°C: 129 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: -

 

N2XH 1x35 mm2 Flex

Nexans ref. 10582539

  • Packaging: Drum (1000m)
  • Conductor shape: Round, multi stranded
  • Conductor flexibility: Flexible class 5
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 226 A
  • Permissible current rating buried/direct 20°C: 129 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x4 mm2

Nexans ref. 10544999

  • Packaging: Drum (1000m)
  • Conductor shape: Circular solid (RE)
  • Conductor flexibility: Solid class 1
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 56 A
  • Permissible current rating buried/direct 20°C: 39 A
  • Bending factor when laying: 8 (xD)
  • U.V resistance: -

 

N2XH 1x4 mm2

Nexans ref. 10556684

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 56 A
  • Permissible current rating buried/direct 20°C: 39 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance:

 

N2XH 1x400 mm2

Nexans ref. 10572963

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 1085 A
  • Permissible current rating buried/direct 20°C: 464 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x400 mm2

Nexans ref. 10588161

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 1085 A
  • Permissible current rating buried/direct 20°C: 464 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x400 mm2 Flex

Nexans ref. 10572980

  • Packaging: Drum (1000m)
  • Conductor shape: Round, multi stranded
  • Conductor flexibility: Flexible class 5
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 1085 A
  • Permissible current rating buried/direct 20°C: 464 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x50 mm2

Nexans ref. 10541114

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 275 A
  • Permissible current rating buried/direct 20°C: 153 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: -

 

N2XH 1x50 mm2

Nexans ref. 10588154

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 275 A
  • Permissible current rating buried/direct 20°C: 153 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x500 mm2 Flex

Nexans ref. 10580193

  • Packaging: Drum (1000m)
  • Conductor shape: Round, multi stranded
  • Conductor flexibility: Flexible class 5
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 1253 A
  • Permissible current rating buried/direct 20°C: 524 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x6 mm2

Nexans ref. 10541913

  • Packaging: Drum (1000m)
  • Conductor shape: Circular solid (RE)
  • Conductor flexibility: Solid class 1
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 71 A
  • Permissible current rating buried/direct 20°C: 49 A
  • Bending factor when laying: 8 (xD)
  • U.V resistance: -

 

N2XH 1x6 mm2

Nexans ref. 10556667

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 71 A
  • Permissible current rating buried/direct 20°C: 49 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: -

 

N2XH 1x70 mm2

Nexans ref. 10540554

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 353 A
  • Permissible current rating buried/direct 20°C: 188 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: -

 

N2XH 1x70 mm2

Nexans ref. 10588156

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 353 A
  • Permissible current rating buried/direct 20°C: 188 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x70 mm2 Flex

Nexans ref. 10582530

  • Packaging: Drum (1000m)
  • Conductor shape: Round, multi stranded
  • Conductor flexibility: Flexible class 5
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 353 A
  • Permissible current rating buried/direct 20°C: 188 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x95 mm2

Nexans ref. 10540555

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 430 A
  • Permissible current rating buried/direct 20°C: 226 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: -

 

N2XH 1x95 mm2

Nexans ref. 10588112

  • Packaging: Drum (1000m)
  • Conductor shape: Circular stranded (RM)
  • Conductor flexibility: Stranded class 2
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 430 A
  • Permissible current rating buried/direct 20°C: 226 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

N2XH 1x95 mm2 Flex

Nexans ref. 10582528

  • Packaging: Drum (1000m)
  • Conductor shape: Round, multi stranded
  • Conductor flexibility: Flexible class 5
  • Core identification: Black
  • Perm. current rating in air 30°C - flat formation: 430 A
  • Permissible current rating buried/direct 20°C: 226 A
  • Bending factor when laying: 5 (xD)
  • U.V resistance: Yes

 

Description

Description

Standards

  • Product
    DIN VDE 0276 part 604; IEC 60502-1

Application

N2XH cable is an installation/power cable widely used in applications requiring high levels of fire safety due to the significant number of human lives at stake, such as: 

  • Industrial and Commercial Electrical Installations
  • Electrical panels and control panels
  • Indoor applications with fire risk (hotels, schools, high-rise buildings, hospitals, data centers, airports, offices etc.)
  • Installations in public places
  • Tunnels and underground infrastructures
  • Wiring for indoor power and lighting circuits in dry environments

Construction

  1. Conductor:Copper
  2. Insulation:XLPE
  3. Outer sheath:LSZH

 

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Copper
Insulation
XLPE (Cross-linked Polyethylene)
Outer sheath
LSZH
Halogen free
IEC 60754-1

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0,6/1 kV

Usage characteristics

Usage characteristics

Operating temperature, range
-20 ... 90 °C
Short-circuit max. conductor temperature
250 °C
Flame retardant
IEC 60332-3 Cat. C
Smoke density
IEC 61034-2
Gases corrosivity
IEC 60754-2
Max. conductor temperature in service
90 °C

Resources

Resources

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close