- Products
- Markets
- Tools & Resources
- About Nexans
- Newsroom
- Search
- Contact us
- Compare
- Sign in
E1VVR 5G 6 #C/SL
Description
Description
Standards
- 
                                            ProductIEC 60502-1
- 
                                            TestIEC 60332-1
- 
                                            NationalELOT 843
Application
Electric cable with copper solid or stranded conductors with PVC insulation and PVC outer sheath.
The cable is suitable for fixed installations, indoor and outdoor.
According to CPR regulation the cable is Euroclass Eca
Cable construction
1. copper conductor
2. PVC insulation
3. PVC outer sheath
Insulation colors according to HD 308
Note: U:circular solid conductor, R:circular stranded conductor, S:sector-shaped stranded conductor
Note: upon request the cable could be available with higher fire retardant performance to meet the standard IEC 60322-3-24 cat C
Characteristics
Characteristics
Construction characteristics
Construction characteristics
                                                                Conductor material
                                                            
                                                            
                                                                Copper 
                                                            
                                                        
                                                                Insulation
                                                            
                                                            
                                                                PVC 
                                                            
                                                        
                                                                Outer sheath
                                                            
                                                            
                                                                PVC 
                                                            
                                                        
                                                                Sheath colour
                                                            
                                                            
                                                                Black 
                                                            
                                                        
                                                                Lead free
                                                            
                                                            
                                                                Yes 
                                                            
                                                        
                                                                Type of conductor
                                                            
                                                            
                                                                R 
                                                            
                                                        
                                                                Conductor flexibility
                                                            
                                                            
                                                                Stranded class 2 
                                                            
                                                        
                                                                Conductor shape
                                                            
                                                            
                                                                Circular 
                                                            
                                                        
                                                                With Green/Yellow core
                                                            
                                                            
                                                                Yes 
                                                            
                                                        
                                                                With smaller neutral conductor
                                                            
                                                            
                                                                - 
                                                            
                                                        Dimensional characteristics
Dimensional characteristics
                                                                Number of cores
                                                            
                                                            
                                                                5 
                                                            
                                                        
                                                                Conductor cross-section
                                                            
                                                            
                                                                6 mm²
                                                            
                                                        
                                                                Phase Conductor Cross Section
                                                            
                                                            
                                                                6 mm²
                                                            
                                                        
                                                                Neutral conductor section (when smaller)
                                                            
                                                            
                                                                6 mm²
                                                            
                                                        
                                                                Ground conductor cross-section
                                                            
                                                            
                                                                6 mm²
                                                            
                                                        
                                                                Nominal insulation thickness
                                                            
                                                            
                                                                1.0 mm
                                                            
                                                        
                                                                Nominal outer sheath thickness
                                                            
                                                            
                                                                1.8 mm
                                                            
                                                        
                                                                Nominal outer diameter
                                                            
                                                            
                                                                18.0 mm
                                                            
                                                        
                                                                Approximate weight
                                                            
                                                            
                                                                550 kg/km
                                                            
                                                        Electrical characteristics
Electrical characteristics
                                                                Rated Voltage Uo/U (Um)
                                                            
                                                            
                                                                0.6/ 1 (1.2) kV 
                                                            
                                                        
                                                                Max. DC resistance of the conductor at 20°C
                                                            
                                                            
                                                                3.08 Ohm/km
                                                            
                                                        
                                                                Permissible current rating when buried
                                                            
                                                            
                                                                56 A
                                                            
                                                        
                                                                Permissible current rating in open air
                                                            
                                                            
                                                                45 A
                                                            
                                                        
                                                                Voltage drop, 3 conductors
                                                            
                                                            
                                                                5.2 V/A.km
                                                            
                                                        
                                                                Voltage drop, single phase
                                                            
                                                            
                                                                - V/A.km
                                                            
                                                        Mechanical characteristics
Mechanical characteristics
                                                                Cable flexibility
                                                            
                                                            
                                                                Rigid 
                                                            
                                                        
                                                                Mechanical resistance to impacts
                                                            
                                                            
                                                                Good 
                                                            
                                                        Usage characteristics
Usage characteristics
                                                                Max. conductor temperature in service
                                                            
                                                            
                                                                70 °C
                                                            
                                                        
                                                                Short-circuit max. conductor temperature
                                                            
                                                            
                                                                160 °C
                                                            
                                                        
                                                                Weather resistance
                                                            
                                                            
                                                                Very good 
                                                            
                                                        Resources
Resources
Documentation
Declaration of Performance
- Declaration of Performance n� : 1000426-GRLA
- Certification Date : 7/3/17
- AVCP (Assessment and Verification of Constancy of Performance) : System 3
- Notified body : 0832
- Declared performance : Eca
Our websites
Select your country to find our products and solutions
- 
                        Africa
                        
                        
                        - Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
 
- Americas
- Asia
- Europe
- Oceania