FLAMEX EN50264-3-1 FR (N)MHXAF 0,6/1kV 1x4

Description

Description

Standards

  • International
    EN 45545 - HL3; EN 50200; EN 50264-3-1; IEC 60331-1 or 2; IEC 60228

FLAMEX® EN50264-3-1 FR flexible power cables maintain circuit integrity in case of fire (according to EN 50200 for 90 minutes) and are fire retardant, low smoke and halogen-free safisfying performance requirements of EN 45545-2-HL3. On top of that, FLAMEX® cables withstand tough working conditions (oil, ozone, temperature variations, etc.).

 

DESIGN

1.  Conductor 
Flexible stranded tinned copper, class 5  acc. to IEC 60228
Mineral tape

2.  Insulation
Cross-linked compound type EI 109  acc. to EN 50264-1
Oil, diesel, ozone and UV resistant
Colour: black

Example of marking: FLAMEX type EN 50264-3-1 FR 600 V mm² M (N)MHXAF-FR 0,6/1kV
I NEXANS I WW-YYYY

 

FIRE SAFETY

FLAMEX® FR TYPE EN 50264-3-1 power cables are conform to EN 45545-2 HL3
Fire resistant according to EN 50200 / IEC 60331-1 or -2

GUIDE TO USE

  • Cabling rules are given in EN 50343 and EN 50355
  • Permissible current carrying capacities: values and calculation method are given in EN 50343
  • Bending radius:
    • Static use: 3 x outer cable diameter if D ≤ 10mm / 5 x outer cable diameter if D > 10mm
    • For installation and occasional movements: 10 x outer cable diameter

Characteristics

Characteristics

Construction characteristics

Construction characteristics

Conductor material
Tin plated copper
Conductor flexibility
Flexible class 5
Insulation
Cross-linked compound
Halogen free
EN 60754-1 & EN 60684-2
Insulation colour
Black

Dimensional characteristics

Dimensional characteristics

Conductor cross-section
4 mm²
Minimum outer diameter
4.5 mm
Maximum outer diameter
4.9 mm
Approximate weight
46 kg/km
Conductor diameter
- mm

Electrical characteristics

Electrical characteristics

Rated Voltage Uo/U (Um)
0.6/ 1 (1.2) kV

Usage characteristics

Usage characteristics

Fire resistant
IEC 60331­-1 or -2
Flame retardant
IEC 60332-1-2
Fire retardant
EN 60332-3-24; EN 60332-3-25
Smoke density
EN/IEC 61034-2
Gases toxicity
EN 50305-9.2
Operating temperature, range
-40 ... 90 °C
Max. conductor temperature in service
90 °C
Overload maximum core temperature
120 °C
Chemical resistance
Good
Ozone resistance
Yes
U.V resistance
Yes
Short-circuit max. conductor temperature
200 °C

Resources

Resources

Documentation

xls — 0 B
xls — 0 B

Contact us

Topics on which you wish to get more informations:

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close

Contact us

Required fields*

Please check your entry and try again.

An email address must contain a single @

Personal data protector

You have the right to object to the processing of your personal data and/or their use for direct marketing or commercial purposes

Thank you!

Thanks for contacting us. We will be in touch with you shortly.

Error

An error occurred. Please try again.

Close